No item(s) available in cart.

API RP 2X Reference Standards LEVEL A BLOCK (INCH VERSION)

INCH VERSION

API RP 2X Reference Standards LEVEL A BLOCK (INCH VERSION) Special Alloy

API RP 2X Reference Standards LEVEL A BLOCK (INCH VERSION) Special Alloy The reference reflector for establishing the scanning sensitivity must be compatible with the flaw acceptance criteria and provide sufficient sensitivity to ensure detection of the smallest discontinuity of interest. For ultrasonic examination at Level A acceptance criteria, the side of a 1/16-inch (1.6-millimeter) drilled hole provides an excellent reference for use with all transducers. The thickness and length of the block containing the drilled hole should permit evaluation of reference sensitivity at the longest metal path distance anticipated in the actual examination. In addition to the side-drilled holes employed for evaluation of all discontinuities in the body of the weld, two 1/16-inch deep notches are suggested as reference standards to be used in evaluating root reflector in butt or T, K, and Y connections welded from one side only. DIMENSION : 9" (L) X 2" (W) X 1" (T) Note : “T” based on the material and equipment that will be used. Block Contains : One Side Drill Hole of Dia Ø1/16" Deep 1½" Two notch 2"(L) X 3/32" (W) X 1/16"(D) Material : Special Alloy

API RP 2X Reference Standards LEVEL A BLOCK (INCH VERSION) 4340 Steel

API RP 2X Reference Standards LEVEL A BLOCK (INCH VERSION) 4340 Steel The reference reflector for establishing the scanning sensitivity must be compatible with the flaw acceptance criteria and provide sufficient sensitivity to ensure detection of the smallest discontinuity of interest. For ultrasonic examination at Level A acceptance criteria, the side of a 1/16-inch (1.6-millimeter) drilled hole provides an excellent reference for use with all transducers. The thickness and length of the block containing the drilled hole should permit evaluation of reference sensitivity at the longest metal path distance anticipated in the actual examination. In addition to the side-drilled holes employed for evaluation of all discontinuities in the body of the weld, two 1/16-inch deep notches are suggested as reference standards to be used in evaluating root reflector in butt or T, K, and Y connections welded from one side only. DIMENSION : 9" (L) X 2" (W) X 1" (T) Note : “T” based on the material and equipment that will be used. Block Contains : One Side Drill Hole of Dia Ø1/16" Deep 1½" Two notch 2"(L) X 3/32" (W) X 1/16"(D) Material : 4340 Steel

API RP 2X Reference Standards LEVEL A BLOCK (INCH VERSION) 1018 Steel

API RP 2X Reference Standards LEVEL A BLOCK (INCH VERSION) 1018 Steel The reference reflector for establishing the scanning sensitivity must be compatible with the flaw acceptance criteria and provide sufficient sensitivity to ensure detection of the smallest discontinuity of interest. For ultrasonic examination at Level A acceptance criteria, the side of a 1/16-inch (1.6-millimeter) drilled hole provides an excellent reference for use with all transducers. The thickness and length of the block containing the drilled hole should permit evaluation of reference sensitivity at the longest metal path distance anticipated in the actual examination. In addition to the side-drilled holes employed for evaluation of all discontinuities in the body of the weld, two 1/16-inch deep notches are suggested as reference standards to be used in evaluating root reflector in butt or T, K, and Y connections welded from one side only. DIMENSION : 9" (L) X 2" (W) X 1" (T) Note : “T” based on the material and equipment that will be used. Block Contains : One Side Drill Hole of Dia Ø1/16" Deep 1½" Two notch 2"(L) X 3/32" (W) X 1/16"(D) Material : 1018 Steel

API RP 2X Reference Standards LEVEL A BLOCK (INCH VERSION) STAINLESS STEEL 304

API RP 2X Reference Standards LEVEL A BLOCK (INCH VERSION) STAINLESS STEEL 304 The reference reflector for establishing the scanning sensitivity must be compatible with the flaw acceptance criteria and provide sufficient sensitivity to ensure detection of the smallest discontinuity of interest. For ultrasonic examination at Level A acceptance criteria, the side of a 1/16-inch (1.6-millimeter) drilled hole provides an excellent reference for use with all transducers. The thickness and length of the block containing the drilled hole should permit evaluation of reference sensitivity at the longest metal path distance anticipated in the actual examination. In addition to the side-drilled holes employed for evaluation of all discontinuities in the body of the weld, two 1/16-inch deep notches are suggested as reference standards to be used in evaluating root reflector in butt or T, K, and Y connections welded from one side only. DIMENSION : 9" (L) X 2" (W) X 1" (T) Note : “T” based on the material and equipment that will be used. Block Contains : One Side Drill Hole of Dia Ø1/16" Deep 1½" Two notch 2"(L) X 3/32" (W) X 1/16"(D) Material : STAINLESS STEEL 304.

API RP 2X Reference Standards LEVEL A BLOCK (INCH VERSION) STAINLESS STEEL 316

API RP 2X Reference Standards LEVEL A BLOCK (INCH VERSION) STAINLESS STEEL 316 The reference reflector for establishing the scanning sensitivity must be compatible with the flaw acceptance criteria and provide sufficient sensitivity to ensure detection of the smallest discontinuity of interest. For ultrasonic examination at Level A acceptance criteria, the side of a 1/16-inch (1.6-millimeter) drilled hole provides an excellent reference for use with all transducers. The thickness and length of the block containing the drilled hole should permit evaluation of reference sensitivity at the longest metal path distance anticipated in the actual examination. In addition to the side-drilled holes employed for evaluation of all discontinuities in the body of the weld, two 1/16-inch deep notches are suggested as reference standards to be used in evaluating root reflector in butt or T, K, and Y connections welded from one side only. DIMENSION : 9" (L) X 2" (W) X 1" (T) Note : “T” based on the material and equipment that will be used. Block Contains : One Side Drill Hole of Dia Ø1/16" Deep 1½" Two notch 2"(L) X 3/32" (W) X 1/16"(D) Material : STAINLESS STEEL 316.

API RP 2X Reference Standards LEVEL A BLOCK (INCH VERSION) TITANIUM

API RP 2X Reference Standards LEVEL A BLOCK (INCH VERSION) TITANIUM The reference reflector for establishing the scanning sensitivity must be compatible with the flaw acceptance criteria and provide sufficient sensitivity to ensure detection of the smallest discontinuity of interest. For ultrasonic examination at Level A acceptance criteria, the side of a 1/16-inch (1.6-millimeter) drilled hole provides an excellent reference for use with all transducers. The thickness and length of the block containing the drilled hole should permit evaluation of reference sensitivity at the longest metal path distance anticipated in the actual examination. In addition to the side-drilled holes employed for evaluation of all discontinuities in the body of the weld, two 1/16-inch deep notches are suggested as reference standards to be used in evaluating root reflector in butt or T, K, and Y connections welded from one side only. DIMENSION : 9" (L) X 2" (W) X 1" (T) Note : “T” based on the material and equipment that will be used. Block Contains : One Side Drill Hole of Dia Ø1/16" Deep 1½" Two notch 2"(L) X 3/32" (W) X 1/16"(D) Material : TITANIUM.

API RP 2X Reference Standards LEVEL A BLOCK (INCH VERSION) ALUMINUM 7075-T6

API RP 2X Reference Standards LEVEL A BLOCK (INCH VERSION) ALUMINUM 7075-T6 The reference reflector for establishing the scanning sensitivity must be compatible with the flaw acceptance criteria and provide sufficient sensitivity to ensure detection of the smallest discontinuity of interest. For ultrasonic examination at Level A acceptance criteria, the side of a 1/16-inch (1.6-millimeter) drilled hole provides an excellent reference for use with all transducers. The thickness and length of the block containing the drilled hole should permit evaluation of reference sensitivity at the longest metal path distance anticipated in the actual examination. In addition to the side-drilled holes employed for evaluation of all discontinuities in the body of the weld, two 1/16-inch deep notches are suggested as reference standards to be used in evaluating root reflector in butt or T, K, and Y connections welded from one side only. DIMENSION : 9" (L) X 2" (W) X 1" (T) Note : “T” based on the material and equipment that will be used. Block Contains : One Side Drill Hole of Dia Ø1/16" Deep 1½" Two notch 2"(L) X 3/32" (W) X 1/16"(D) Material : ALUMINUM 7075-T6

API RP 2X Reference Standards LEVEL A BLOCK (INCH VERSION) INCONEL 625

API RP 2X Reference Standards LEVEL A BLOCK (INCH VERSION) INCONEL 625 The reference reflector for establishing the scanning sensitivity must be compatible with the flaw acceptance criteria and provide sufficient sensitivity to ensure detection of the smallest discontinuity of interest. For ultrasonic examination at Level A acceptance criteria, the side of a 1/16-inch (1.6-millimeter) drilled hole provides an excellent reference for use with all transducers. The thickness and length of the block containing the drilled hole should permit evaluation of reference sensitivity at the longest metal path distance anticipated in the actual examination. In addition to the side-drilled holes employed for evaluation of all discontinuities in the body of the weld, two 1/16-inch deep notches are suggested as reference standards to be used in evaluating root reflector in butt or T, K, and Y connections welded from one side only. DIMENSION : 9" (L) X 2" (W) X 1" (T) Note : “T” based on the material and equipment that will be used. Block Contains : One Side Drill Hole of Dia Ø1/16" Deep 1½" Two notch 2"(L) X 3/32" (W) X 1/16"(D) Material : INCONEL 625.

API RP 2X Reference Standards LEVEL A BLOCK (INCH VERSION) MONAL 800

API RP 2X Reference Standards LEVEL A BLOCK (INCH VERSION) MONAL 800 The reference reflector for establishing the scanning sensitivity must be compatible with the flaw acceptance criteria and provide sufficient sensitivity to ensure detection of the smallest discontinuity of interest. For ultrasonic examination at Level A acceptance criteria, the side of a 1/16-inch (1.6-millimeter) drilled hole provides an excellent reference for use with all transducers. The thickness and length of the block containing the drilled hole should permit evaluation of reference sensitivity at the longest metal path distance anticipated in the actual examination. In addition to the side-drilled holes employed for evaluation of all discontinuities in the body of the weld, two 1/16-inch deep notches are suggested as reference standards to be used in evaluating root reflector in butt or T, K, and Y connections welded from one side only. DIMENSION : 9" (L) X 2" (W) X 1" (T) Note : “T” based on the material and equipment that will be used. Block Contains : One Side Drill Hole of Dia Ø1/16" Deep 1½" Two notch 2"(L) X 3/32" (W) X 1/16"(D) Material : MONAL 800.

© 2024 NDE FLAW TECH. All Right Reserved.