No item(s) available in cart.

Individual NDT Training and Examination NDT Flawed Specimen

Pipe to Nozzle Ultrasonic Test Flaw Specimen Set On Full Penetration

Pipe to Nozzle Ultrasonic Test Flaw Specimen Set On Full Penetration Pipe to Nozzle Ultrasonic Test Flaw Specimen 0.6” (Set On Full Penetration) Geometry: Pipe to Flange Nozzle Joint with Weld length (Set On Full Penetration Joint) Customized Calibration Test Block and Flaw Specimen also available. Flaws: 3 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.

Pipe to Nozzle Ultrasonic Test Flaw Specimen Set Through Partial Penetration Joint

Pipe to Nozzle Ultrasonic Test Flaw Specimen Set Through Partial Penetration Joint Geometry: Pipe to Flange Nozzle Joint with Weld length with (Set Through Partial Penetration Joint) Customized Calibration Test Block and Flaw Specimen also available. Flaws: 3 or 4 per specimen, randomly placed Specimen Tolerance: +/- 0.080". Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.

Pipe to Nozzle Ultrasonic Test Flawed Specimens Set through Full Penetration

Pipe to Nozzle Ultrasonic Test Flawed Specimens Set through Full Penetration Pipe to Nozzle Ultrasonic Test Flawed Specimens (Set through Full Penetration) Geometry: Pipe to Flange Nozzle Joint with Weld length with (Set Through Full Penetration Joint) Customized Calibration Test Block and Flaw Specimen also available. Flaws: 3 or 4 per specimen, randomly placed Specimen Tolerance: +/- 0.080". Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.

Tubular Nodes Weld UT Flaw Test Specimen

Tubular Nodes Weld UT Flaw Test Specimen Tubular Nodes Weld UT Flaw Test Specimen (Ultrasonic Test) Tubular Nodes 0.5” to 0.8” 30ᵒ UT Flawed Specimens Customized Calibration Test Block and Flaw Specimen also available. Flaws: 3 or 4 per specimen, randomly placed Specimen Tolerance: +/- 0.080". Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.

Magnetic Flux Leakage MFL Floor Inspection Reference Standard

Magnetic Flux Leakage MFL Floor Inspection Reference Standard Round Bottom Hole Reference Plate with 4 RBH, RBH dia depth and location as per eddyfi recommendation Material: Mild Steel Customized Calibration Test Block and Flaw Specimen also available.

PAUT And TOFD Pipe to Pipe Weld Joint Flawed Specimen

PAUT And TOFD Pipe to Pipe Weld Joint Flawed Specimen Phased Array Ultrasonic Testing (PAUT)-Weld Joint Flawed Specimen 10" Dia- Time-of-flight diffraction ultrasonics

PAUT And TOFD Plate TO Plate Weld Flawed Specimen

PAUT And TOFD Plate TO Plate Weld Flawed Specimen PAUT And TOFD Plate TO Plate Weld Flawed Specimen Double V ASYMMETRICAL Time-of-flight diffraction ultrasonic (TOFD)-PLATE Weld Joint Flawed Specimen-Phased Array Ultrasonic Testing (PAUT) Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets. Customized Calibration Test Block and Flaw Specimen also available.

Plate Ultrasonic Test Practical Exam Flaw Specimen

Plate Ultrasonic Test Practical Exam Flaw Specimen Plate Ultrasonic Practical Exam flawed Test specimens. Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets. Customized Calibration Test Block and Flaw Specimen also available.

Pipe Ultrasonic Test Practical Exam Flaw Specimen

Pipe Ultrasonic Test Practical Exam Flaw Specimen Pipe Ultrasonic Practical Exam flawed Test specimens. Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.

T-Plate Ultrasonic Test Practical Exam Flaw Specimen

T-Plate Ultrasonic Test Practical Exam Flaw Specimen T-Plate Ultrasonic Practical Exam flawed Test specimens. Flaws: 3, randomly placed Standard Tolerance: +/-4mm. Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.

Plate Radiographic Test Practical Exam Flaw Specimen

Plate Radiographic Test Practical Exam Flaw Specimen Plate Radiographic Practical Exam flawed Test specimens. Geometry: 0.4” (T) x 8.0” (W) x 10.0” (L). Flaws: 3, randomly placed Standard Tolerance: +/-4mm. Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.

Pipe Radiographic Test Practical Exam Flaw Specimen

Pipe Radiographic Test Practical Exam Flaw Specimen Pipe Radiographic Practical Exam flawed Test specimens. Flaws: 3, randomly placed Standard Tolerance: +/-4mm. Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.

T-Plate Radiographic Test Practical Exam Flaw Specimen

T-Plate Radiographic Test Practical Exam Flaw Specimen T-Plate Radiographic Practical Exam flawed Test specimens. Flaws: 3, randomly placed Standard Tolerance: +/-4mm. Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.

Plate Magnetic Particle Test Practical Exam Flaw Specimen

Plate Magnetic Particle Test Practical Exam Flaw Specimen Plate Magnetic Particle Practical Exam flawed Test specimens. Flaws: 3, randomly placed Standard Tolerance: +/-4mm. Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.

Pipe Magnetic Particle Test Practical Exam Flaw Specimen

Pipe Magnetic Particle Test Practical Exam Flaw Specimen Pipe Magnetic Particle Practical Exam flawed Test specimens. Geometry: 0.25” (T) x Ø4”x 10.0” (L). Flaws: 3, randomly placed Standard Tolerance: +/-4mm. Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.

T-Plate Magnetic Particle Test Practical Exam Flaw Specimen

T-Plate Magnetic Particle Test Practical Exam Flaw Specimen T-Plate Magnetic Particle Practical Exam flawed Test specimens. Flaws: 3, randomly placed Standard Tolerance: +/-4mm. Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.

Plate Dye Penetrant Test Practical Exam Flaw Specimen

Plate Dye Penetrant Test Practical Exam Flaw Specimen Plate Dye Penetrant Test Practical Exam flawed Test specimens. Flaws: 3, randomly placed Standard Tolerance: +/-4mm. Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.

Pipe Dye Penetrant Test Practical Exam Flaw Specimen

Pipe Dye Penetrant Test Practical Exam Flaw Specimen Pipe Dye Penetrant Test Practical Exam flawed Test specimens. Flaws: 3, randomly placed Standard Tolerance: +/-4mm. Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.

T-Plate Dye Penetrant Test Practical Exam Flaw Specimen

T-Plate Dye Penetrant Test Practical Exam Flaw Specimen T-Plate Dye Penetrant Test Practical Exam flawed Test specimens. Flaws: 3, randomly placed Standard Tolerance: +/-4mm. Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.

Plate Visual Test Practical Exam Flaw Specimen

Plate Visual Test Practical Exam Flaw Specimen Plate Visual Test Practical Exam flawed Test specimens. Flaws: 3, randomly placed Standard Tolerance: +/-4mm. Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.

Pipe Visual Test Practical Exam Flaw Specimen

Pipe Visual Test Practical Exam Flaw Specimen Pipe Visual Test Practical Exam flawed Test specimens. Flaws: 3, randomly placed Standard Tolerance: +/-4mm. Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.

T-Plate Visual Test Practical Exam Flaw Specimen

T-Plate Visual Test Practical Exam Flaw Specimen T-Plate Visual Test Practical Exam flawed Test specimens. Flaws: 3, randomly placed Standard Tolerance: +/-4mm. Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.

Rod Stock Ultrasonic Test Practical Exam Flawed Specimen

Rod Stock Ultrasonic Test Practical Exam Flawed Specimen Rod & Bar Stock Ultrasonic Practical Exam flawed test specimens. Flaws: 3, randomly placed Standard Tolerance: +/-0.150" (4mm). Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.

Nozzle to Plate Weld Ultrasonic Test Practical Exam Flaw Specimen

Nozzle to Plate Weld Ultrasonic Test Practical Exam Flaw Specimen Nozzle to Plate Weld Ultrasonic Practical Exam flawed specimens. Flaws: 3, randomly placed Standard Tolerance: +/-0.150" (4mm). Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.

Pipe to Socket Weld Flaw Specimen

Pipe to Socket Weld Flaw Specimen Pipe to Socket Weld Magnetic Particle/Liquid Penetrant Exam Flawed Specimens. Flaws: 3, randomly placed Standard Tolerance: +/-0.150" (4mm). Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.

Pipe to Nozzle Ultrasonic Test Flawed Specimens Set on Partial Penetration Joint

Pipe to Nozzle Ultrasonic Test Flawed Specimens Set on Partial Penetration Joint Pipe to Nozzle Ultrasonic Test Flawed Specimens (Set on Partial Penetration Joint) Geometry: Pipe to Flange Nozzle Joint with Weld length (Set On Partial Penetration Joint). Customized Calibration Test Block and Flaw Specimen also available. Flaws: 3 or 4 per specimen, randomly placed Specimen Tolerance: +/- 0.080" Documentation: NDT Verification Reports, C of C, CAD Drawings and Test Sheets.

© 2022 NDE FLAW TECH. All Right Reserved.Designed & Developed by Innov Touch Technologies Pvt Ltd.